Most Recent Pins (55)
Bryan Merlin
Blue Wave Heating and Air LLC provided an Annual HVAC Protection Plan in Austin, Texas. The service included pre-summer and pre-winter system inspections, thermostat checks, condenser and evaporator coil cleaning, wiring assessments, and safety control verifications. Technicians also inspected gas piping, airflow, and motors to keep the HVAC system operating effectively year-round.
Bryan Merlin
Blue Wave Heating and Air LLC completed a full HVAC system replacement in Johnson City, Texas. Technicians replaced the condenser, furnace, coil, and air handler. They disposed of the old system, cleaned and checked refrigerant lines, installed a new condenser pad and safety switches, and updated gas piping to meet code requirements.
Bryan Merlin
Blue Wave Heating and Air LLC removed and disposed of an old HVAC system and installed a new one in Cedar Park, Texas. The work included replacing the condenser, furnace, and coil air handler, installing drain safety switches, adjusting gas piping, cleaning refrigerant lines, and mounting the condenser on a rooftop pad using a crane.
Bryan Merlin
Blue Wave Heating and Air LLC performed HVAC system diagnostics in Dripping Springs, Texas. The service included clearing and repairing a PVC drain with up to two fittings and replacing a 7.5 MFD run capacitor to restore system function.
Bryan Merlin
Blue Wave Heating and Air LLC performed quarterly HVAC maintenance in Cedar Park, Texas. Services included refrigerant checks, thermostat calibration, coil inspection, drain cleaning, and electrical testing. Condenser coils are cleaned annually, and drains are vacuumed quarterly. Technicians replaced air filters for multiple systems across various rooms, ensuring efficient heating and cooling year-round.
Bryan Merlin
Blue Wave Heating and Air LLC completed a condensate pump replacement in Dripping Springs, Texas. The service involved removing the faulty pump and installing a new unit to support proper drainage in the HVAC system. This helps prevent water damage and ensures the system continues operating efficiently.
Bryan Merlin
Blue Wave Heating and Air LLC completed an Annual HVAC Protection Plan in Austin, Texas. Technicians performed seasonal inspections, adjusted thermostats, cleaned system components, inspected gas piping and venting, and tested system airflow. Customers receive repair recommendations and 15% off needed repairs during the year for additional systems beyond initial coverage.
Bryan Merlin
Blue Wave Heating and Air LLC installed a 60,000 BTU ceiling-suspended mini-split system, a Manitowoc ice machine system, and a restroom exhaust fan with ventilation in Cedar Park, Texas. The work included refrigerant line routing, system commissioning, drain connections, and code-compliant ventilation to support indoor comfort and equipment performance.
Bryan Merlin
Technicians in Johnson City, Texas replaced a leaking minisplit evaporator coil in an indoor unit. They removed refrigerant from the roof, replaced the coil, pressure tested the system, performed a deep vacuum, and recharged it with R-410a. The service also included clearing the drain lines for other minisplit units.
Bryan Merlin
Blue Wave Heating and Air LLC replaced a 3-ton Carrier evaporator coil and TXV due to a leak in Dripping Springs, Texas. The team installed a like-for-like unit, performed a deep vacuum, replaced copper line filters, and recharged R-410a refrigerant. The system includes a one-year labor warranty and uses parts covered under warranty.
Bryan Merlin
Blue Wave Heating and Air LLC replaced a Carrier defrost board and contactor starting relay in Austin, Texas. The service included cleaning the outdoor condenser. All replacement parts come with a one-year warranty.
Bryan Merlin
Blue Wave Heating and Air LLC added R22 refrigerant by the pound to an existing HVAC system in Burnet, Texas. This service supports proper cooling performance and helps maintain system efficiency in high-temperature conditions.
Bryan Merlin
Blue Wave Heating and Air LLC removed an old wall-mounted unit and outdoor condenser in Cedar Park, Texas. The team installed a new Daikin indoor unit and outdoor condenser, connected refrigerant lines, completed electrical hookups, and conducted full system startup with performance testing. The installation includes a surge protector and a metal cover for the lineset.
Bryan Merlin
Blue Wave Heating and Air LLC replaced a warranty-covered evaporator coil and a Nordyne blower motor in a mobile home in Leander, Texas. The job included installing a new valve and liquid filter drier. The blower motor, built for narrow duct systems, was special-ordered due to its compatibility requirements.
Bryan Merlin
Blue Wave Heating and Air LLC completed HVAC system upgrades in Round Rock, Texas. Work included replacing two plenums, installing a metal transition, upgrading gas piping to code, adding a new return duct, fixing a refrigerant leak, installing a TXV valve, and replacing the furnace's control board and gas valve under warranty.
Bryan Merlin
BLUE WAVE HEATING AND AIR LLC completed a scheduled HVAC seasonal visit in Johnson City, Texas. This service supports customers with an existing Total Protection plan and includes routine system checks for either winter or summer readiness.
Bryan Merlin
Blue Wave Heating and Air LLC performed an HVAC system diagnostic and drain cleaning in Austin, Texas. The visit included an inspection to identify performance issues followed by a drain line cleaning using appropriate methods to restore system function.
Bryan Merlin
Blue Wave Heating and Air LLC installed a sound enclosure kit for large frame scroll compressors in Austin, Texas. The upgrade reduced operating noise from 74 dBa to 69 dBa, improving sound control for compressors under 17.3 inches tall or 7.3 inches in diameter.
Bryan Merlin
Blue Wave Heating and Air LLC located and repaired a short or circuit issue at level 3 in Cedar Park, Texas. The team fixed the electrical fault and tested the entire system to ensure it functioned correctly.
Bryan Merlin
Blue Wave Heating and Air LLC completed an AC tune-up in Johnson City, Texas. Technicians serviced two 5-ton Carrier units by checking refrigerant levels, cleaning the condenser, inspecting wiring, and testing system startup. Although cooling was restored, the units remain undersized for the commercial space and do not cool the full shop effectively.
Bryan Merlin
Blue Wave Heating and Air LLC cleaned an RTU drain pan and verified proper drainage in Austin, Texas. The team also inspected system operations and adjusted belt tension to improve performance.
Bryan Merlin
Blue Wave Heating and Air LLC installed a customer-supplied multi-zone mini-split system in Austin, Texas. The project included mounting two indoor wall units, installing an outdoor condenser, running refrigerant lines, connecting control wiring, setting up drainage, pressure testing, and applying line set covers. A two-year labor warranty was provided, excluding manufacturer parts and certain structural work.
Bryan Merlin
Blue Wave Heating and Air LLC performed an AC tune-up in Johnson City, Texas. The service included checking refrigerant levels, testing electrical components, cleaning the condenser, inspecting the evaporator coil, and adjusting the outdoor king valve. Technicians also examined the compressor and provided maintenance recommendations based on system performance.
Bryan Merlin
Blue Wave Heating and Air LLC performed an AC tune-up in Johnson City, Texas. The service included checking refrigerant levels, testing the thermostat, inspecting electrical components, cleaning the condenser, and assessing the compressor. The technician provided recommendations for any additional maintenance or repairs needed to maintain proper system performance.
Bryan Merlin
Blue Wave Heating and Air LLC installed a customer-supplied multi-zone mini-split system in Austin, Texas. The project included two indoor wall-mounted units, outdoor condenser mounting, control wiring, refrigerant lines, drainage, and line set cover installation. Technicians performed vacuum pulls, pressure tests, and torque checks to meet standard HVAC practices.
Bryan Merlin
BLUE WAVE HEATING AND AIR LLC inspected an HVAC system in Johnson City, Texas. Technicians identified a refrigerant leak and added one pound of R-22 to maintain system function for tenants until a full repair quote could be provided. The visit included a diagnostic assessment of the system’s condition.
Bryan Merlin
Blue Wave Heating and Air LLC completed a full HVAC system replacement in Leander, Texas. The project included removing an old gas furnace, installing a new 3-ton two-stage system, replacing the outdoor condenser and thermostat, sealing duct connections, and performing system testing. The installation includes a 10-year parts and labor warranty and a 2-year maintenance contract.
Bryan Merlin
Blue Wave Heating and Air LLC performed annual HVAC maintenance in Leander, Texas. Technicians completed pre-summer and pre-winter system inspections, including checks of thermostats, coils, motors, filters, burners, and safety controls. The service ensures seasonal readiness and offers repair options with a 15% discount on any repair identified during the year.
Bryan Merlin
Blue Wave Heating and Air LLC replaced an outdated HVAC system in Buda, Texas. The job included installing a new 3-ton, 2-stage air conditioner, updating the thermostat to a WiFi model, replacing the outdoor condenser, sealing system connections, and adding a side return in the hallway. Final testing ensured optimal airflow and efficiency.
Bryan Merlin
A technician from Blue Wave Heating and Air LLC replaced an OEM furnace blower motor in Austin, Texas. This service restored proper airflow and improved the furnace’s performance. Timely motor replacement helps prevent furnace failure and supports consistent indoor heating efficiency.
Bryan Merlin
Blue Wave Heating and Air LLC replaced a condenser fan motor and installed a Turbo200X capacitor in Austin, Texas. The new fan motor runs at 1075 RPM and serves as a cost-effective replacement for OEM models. The Turbo200X capacitor supports compressor and fan motor startup, both backed by a five-year part and one-year labor warranty.
Bryan Merlin
Blue Wave Heating and Air LLC completed an HVAC diagnostic visit in Austin, Texas. The technician assessed the system to identify performance or functionality issues. After the evaluation, recommendations were prepared based on the specific condition and needs of the equipment.
Bryan Merlin
Blue Wave Heating and Air LLC performed an annual HVAC maintenance service in Georgetown, Texas. The service included two seasonal inspections to assess components such as thermostats, coils, burners, motors, and electrical systems. Technicians cleaned, adjusted, and tested HVAC units to improve performance and offered repair recommendations. Customers receive 15% off repairs identified during these visits.
Bryan Merlin
Blue Wave Heating and Air LLC completed a pre-sale HVAC maintenance and inspection in Georgetown, Texas. Technicians assessed refrigerant levels, tested system performance, inspected both heat exchangers, and identified bacterial growth, corrosion, poor airflow, and safety code violations. Due to multiple issues in both 2014 Rheem units, full replacement of the upstairs and downstairs systems was recommended.
Bryan Merlin
Blue Wave Heating and Air LLC replaced a failed 45 + 5 MFD dual capacitor in an outdoor condenser unit in Georgetown, Texas. The technician completed a full diagnostic assessment before providing the repair. This service restored condenser function and ensured system reliability with a five-year part warranty.
Bryan Merlin
Blue Wave Heating and Air LLC performed an AC tune-up in Cedar Park, Texas. The service included checking refrigerant levels, testing the thermostat, inspecting electrical components, cleaning the condenser, and verifying compressor function. The technician also examined the evaporator coil and provided a maintenance recommendation after the inspection.
Bryan Merlin
Blue Wave Heating and Air LLC completed an AC tune-up in Dripping Springs, Texas. The service included checking refrigerant levels, testing the thermostat, inspecting electrical components, cleaning the condenser, and verifying fan motor operation. The technician provided a detailed assessment and recommended any necessary maintenance or repairs for continued system performance.
Bryan Merlin
Blue Wave Heating and Air LLC completed an AC tune-up in Austin, Texas. The service included checking refrigerant levels, testing the thermostat, inspecting electrical components, cleaning the condenser, and evaluating the compressor. Technicians also checked the drain line and fan motor. After the service, they provided recommendations for any needed maintenance or repairs.
Bryan Merlin
Blue Wave Heating and Air LLC inspected an HVAC system in Austin, Texas. The service focused on diagnosing system issues and vacuuming the condensate drain line to restore proper drainage. The visit identified specific maintenance needs and provided clear next steps for system performance.
Bryan Merlin
Blue Wave Heating and Air LLC replaced an outdated HVAC system in Lago Vista, Texas. The team installed a 16 SEER2 heat pump and air handler, upgraded the thermostat to a WiFi-enabled model, sealed ductwork, added safety switches, and tested the system for efficiency. The project included warranty coverage and a two-year maintenance plan.
Bryan Merlin
BLUE WAVE HEATING AND AIR LLC inspected an HVAC system in Austin, Texas. The technician completed a diagnostic visit and identified specific issues. The service included evaluating system performance and recommending solutions. A 13–34 HP Rescue ECM motor with module was assessed as part of the repair plan.
Bryan Merlin
Blue Wave Heating and Air LLC completed an HVAC diagnostic and repair service in Leander, Texas. The technician replaced a faulty two-pole 25–30 AMP 24V contactor and upgraded the thermostat to a Honeywell T4 model after evaluating system performance during the initial visit.
Bryan Merlin
BLUE WAVE HEATING AND AIR LLC diagnosed and repaired a seized pump on a water loop at River Place Elementary in Austin, Texas. The team restored full heating and cooling function and completed a TXV replacement for Leander Independent School District using parts supplied directly from the vendor.
Bryan Merlin
Blue Wave Heating and Air LLC performed HVAC drain clearing in Dripping Springs, Texas. Technicians identified a clogged AC drain that caused system shutdowns and water under the carpet. The team conducted a diagnostic inspection and restored proper drainage to prevent further disruption.
Bryan Merlin
Blue Wave Heating and Air LLC replaced an outdated HVAC system in Dripping Springs, Texas. The team installed a 14.3 SEER2-rated system, a new condenser unit, and a WiFi-enabled thermostat. They connected all lines safely, sealed the ductwork, ensured proper drainage, tested performance, and made final adjustments for efficiency. Warranty coverage included parts and labor guarantees.
Bryan Merlin
Blue Wave Heating and Air LLC inspected and repaired RTU8 for a classroom HVAC system in Austin, Texas. Technicians replaced two leaking sensors and added 20 pounds of R410A refrigerant. The unit, a two-stage 15-ton system with two compressors, now operates correctly after refrigerant adjustments in both circuits.
Bryan Merlin
Blue Wave Heating and Air LLC replaced a full HVAC system in Lago Vista, Texas. The project included removing the old air handler and condenser, installing a 16 SEER2 system, updating the thermostat to a WiFi-enabled model, sealing new ducts, and performing full system testing. The installation included a 10-year parts warranty and a 2-year maintenance contract.
Bryan Merlin
A technician inspected and diagnosed an issue with an air conditioning system in Austin, Texas. The visit included a service fee for the assessment. This evaluation helps identify system problems and determine necessary repairs to restore proper function.
Bryan Merlin
Blue Wave Heating and Air LLC installed a complete HVAC system in Round Rock, Texas. The project included rough-in, finish work, copper line sets, indoor and outdoor units, and system startup. The new system uses inverter technology. A 230V electrical hookup is required but not included. The installation carries a 10-year parts and compressor warranty.
Bryan Merlin
Blue Wave Heating and Air LLC diagnosed and repaired an HVAC system in Cedar Park, Texas. The service included replacing the outdoor unit compressor, leak testing, refrigerant recharge with R-410a, deep vacuuming, and thermostat reprogramming for maximum fan speed. Technicians also installed two warranty boards as advised by manufacturer support.
Bryan Merlin
Blue Wave Heating and Air LLC performed extensive drain clearing and PVC pipe repair in Leander, Texas. The team conducted a full HVAC diagnostic and cleaned the horizontal coil and pan inside the air handler. This service helped restore proper system function and addressed potential drainage issues.
Bryan Merlin
Blue Wave Heating and Air LLC completed an HVAC system diagnosis and performed a drain cleaning in Austin, Texas. The team inspected the system, identified the issue, and cleaned the drain to restore proper function and prevent further blockage.
Bryan Merlin
Technicians repaired a leaking HVAC drain pan in Austin, Texas. They removed a faulty manufacturer pipe and reinstalled it using thread sealant. They also cleared and repaired a PVC drain with up to two fittings and added a cap to the drain line to stop backflow during fan operation.
Bryan Merlin
Blue Wave Heating and Air LLC diagnosed an HVAC system in Round Rock, Texas. The service included replacing a Turbo200 multi-use capacitor, installing a contactor with shunt and 40VA transformer, and vacuuming a clogged condensate drain line at the attic p-trap. All parts come with a five-year warranty.
Bryan Merlin
Blue Wave Heating and Air LLC replaced the capacitor and contactor on a Carrier HVAC system and cleared a backed-up attic drain to prevent water damage. This HVAC service took place in Round Rock, Texas.